Easy
System Installation
The system can often be installed without mechanical
or electrical contractors. Inlet and Effluent water supply hoses can be
quickly connected with 1.5-inch camlock connections. The system is mounted
on an aluminum strut frame and can easily be moved into position on a
hand truck. The oxygen generators (one unit on the low flow system and
two on the high flow system) can be plugged into a standard 120-volt wall
outlet. Each oxygen generator draws only 5 amps. If the peristaltic pump
will be used to deliver nutrient amendments such as nitrogen or phosphorus
a third 120-volt outlet is required. The peristaltic pump draws approximately
2 amps. The system is designed for indoor operation with air temperatures
maintained between 40-100 degrees Fahrenheit. The oxygen generators and
peristaltic pump are not explosion-proof and should not be operated in
a corrosive or explosive atmosphere. If the oxygenation system is to be
installed in an environment where explosive vapors might be present the
oxygen generators and chemical feed pump must be located in different
location that is free of corrosive or explosive vapors.
|